None, D. V. A., None, D. S. G., None, D. M. V. P., None, D. M. S. & None, D. S. S. (2026). Correlation Between Leak Test and Ultrasonographic Assessment for Confirming Optimal Laryngeal Mask Airway Placement in Pediatric Patients: A Prospective Observational Study. Journal of Contemporary Clinical Practice, 12(11), 568-574.
MLA
None, Dr. Vrishali Ankalwar, et al. "Correlation Between Leak Test and Ultrasonographic Assessment for Confirming Optimal Laryngeal Mask Airway Placement in Pediatric Patients: A Prospective Observational Study." Journal of Contemporary Clinical Practice 12.11 (2026): 568-574.
Chicago
None, Dr. Vrishali Ankalwar, Dr. Sneha Gandle , Dr. Manish V. Patil , Dr. Mansi Sawarkar and Dr. Sheetal Shinde . "Correlation Between Leak Test and Ultrasonographic Assessment for Confirming Optimal Laryngeal Mask Airway Placement in Pediatric Patients: A Prospective Observational Study." Journal of Contemporary Clinical Practice 12, no. 11 (2026): 568-574.
Harvard
None, D. V. A., None, D. S. G., None, D. M. V. P., None, D. M. S. and None, D. S. S. (2026) 'Correlation Between Leak Test and Ultrasonographic Assessment for Confirming Optimal Laryngeal Mask Airway Placement in Pediatric Patients: A Prospective Observational Study' Journal of Contemporary Clinical Practice 12(11), pp. 568-574.
Vancouver
Dr. Vrishali Ankalwar DVA, Dr. Sneha Gandle DSG, Dr. Manish V. Patil DMVP, Dr. Mansi Sawarkar DMS, Dr. Sheetal Shinde DSS. Correlation Between Leak Test and Ultrasonographic Assessment for Confirming Optimal Laryngeal Mask Airway Placement in Pediatric Patients: A Prospective Observational Study. Journal of Contemporary Clinical Practice. 2026 Nov;12(11):568-574.
Correlation Between Leak Test and Ultrasonographic Assessment for Confirming Optimal Laryngeal Mask Airway Placement in Pediatric Patients: A Prospective Observational Study
Dr. Vrishali Ankalwar
1
,
Dr. Sneha Gandle
2
,
Dr. Manish V. Patil
3
,
Dr. Mansi Sawarkar
4
,
Dr. Sheetal Shinde
5
1
Associate Professor, GMC Nagpur, India.
2
Senior Resident, VDGMC Latur, India.
3
Assistant Professor, GMC Nagpur, India.
4
Assistant Professor, JIET, India.
5
Senior Resident, PCMC PGI, YCM Institute Pimpri-Chinchwad, India.
Background: Accurate confirmation of laryngeal mask airway (LMA) position is essential for effective ventilation and prevention of airway-related complications in pediatric patients. Conventional clinical methods, such as the leak test, provide functional information but do not directly assess anatomical positioning. This study aimed to evaluate the correlation between ultrasonographic (USG) assessment and leak test findings for confirming optimal LMA placement in pediatric patients, with fibreoptic assessment as a reference method. Methods: This prospective observational study was conducted in 37 pediatric patients aged 2–12 years with American Society of Anesthesiologists (ASA) physical status I or II undergoing elective procedures requiring LMA-assisted general anesthesia. Following LMA insertion, device position was assessed using real-time ultrasonography in transverse and parasagittal planes. LMA position was graded according to predefined ultrasound criteria and classified as acceptable or unacceptable placement. LMA position was subsequently evaluated using the leak test and fibreoptic laryngoscopy (FOL). Agreement between assessment methods was analyzed using Cohen’s kappa coefficient. Results: The mean age of patients was 6.47 ± 2.85 years. Successful LMA insertion was achieved on the first attempt in 34 patients (91.9%), with a mean insertion time of 10.38 ± 1.46 seconds. Leak testing demonstrated acceptable placement in all patients (100%). Ultrasonographic assessment identified acceptable LMA positioning in 33 patients (89.2%) and suboptimal positioning in 4 patients (10.8%). Fibreoptic evaluation showed findings consistent with ultrasonography, with acceptable positioning in 33 patients (89.2%) and unacceptable positioning in 4 patients (10.8%). The agreement between leak test and final USG grading was substantial (Cohen’s κ = 0.66). The internal consistency between assessment methods demonstrated a Cronbach’s alpha value of 0.76. Conclusion: Ultrasonography is a reliable, non-invasive method for confirming LMA position in pediatric patients. Although the leak test remains useful for assessing airway function, ultrasonography provides additional anatomical information and may help identify suboptimal LMA placement that can remain undetected by conventional clinical assessment.
Keywords
Laryngeal mask airway
Pediatric anesthesia
Ultrasonography
Fibreoptic laryngoscopy
Leak test
Supraglottic airway device.
INTRODUCTION
The laryngeal mask airway (LMA) is a commonly used supraglottic airway device for airway management in pediatric patients undergoing general anesthesia for elective surgical and diagnostic procedures. Compared with endotracheal intubation, LMA insertion is less invasive, produces fewer airway-related complications, and offers greater hemodynamic stability with a lower incidence of postoperative sore throat and coughing, making it an attractive option in children (1,2).
Although LMA insertion is generally straightforward, successful placement does not necessarily indicate that the device is positioned optimally over the laryngeal inlet. Improper positioning may lead to inadequate ventilation, increased airway leak, elevated airway pressures, gastric insufflation, and an increased risk of pulmonary aspiration. Therefore, accurate confirmation of LMA position is essential to ensure effective ventilation and reduce perioperative airway-related complications (3,4).
Several techniques are available to assess LMA placement, including observation of chest movement, auscultation, capnography, the bubble test, the leak test, ultrasonography (USG), fibreoptic bronchoscopy (FOB), and fibreoptic laryngoscopy (FOL). Among these, the leak test is widely used because it is simple, rapid, non-invasive, and provides a functional assessment of the airway seal. However, it only reflects ventilatory performance and does not provide direct information about the anatomical position of the LMA relative to the laryngeal structures (3,5).
Fibreoptic evaluation is widely regarded as the reference standard for assessing LMA position because it allows direct visualization of the laryngeal inlet. However, it is invasive, requires temporary interruption of ventilation, demands specialized equipment and expertise, and may be limited by airway secretions or blood that obscure visualization (6). In contrast, ultrasonography has emerged as a promising, non-invasive imaging modality for evaluating LMA placement. It enables real-time visualization of the device in relation to surrounding airway structures without interrupting ventilation and has demonstrated good accuracy in identifying suboptimal LMA positioning (7).
Despite the growing interest in ultrasonography for airway assessment, limited evidence is available regarding its correlation with conventional bedside methods, such as the leak test, and fibreoptic assessment in pediatric patients. Establishing the relationship between these techniques may help determine whether ultrasonography can serve as a reliable, non-invasive alternative for confirming optimal LMA placement in routine clinical practice.
Therefore, the present prospective observational study was undertaken to evaluate the correlation between ultrasonographic findings and the leak test for confirming optimal LMA placement in pediatric patients. In addition, fibreoptic laryngoscopic grading was compared with ultrasonographic assessment to determine the ability of ultrasonography to accurately confirm LMA position.
MATERIALS AND METHODS
Study Design and Participants
This prospective observational study was conducted after obtaining approval from the Institutional Ethics Committee. Written informed consent was obtained from the parents or legal guardians of all participants. Thirty-seven pediatric patients aged 2–12 years with American Society of Anesthesiologists (ASA) physical status I or II, scheduled for elective surgical procedures of less than 2 hours under general anesthesia requiring a laryngeal mask airway (LMA), were enrolled. Patients with anticipated difficult airway (based on Mallampati classification and thyromental height), upper respiratory tract infection, previous neck surgery, congenital airway anomalies, congenital heart disease, risk of aspiration, or refusal to participate were excluded.
The sample size of 37 was calculated from a pilot study to achieve 85% statistical power, 5% types I error, and an anticipated effect size of 25%.
Anaesthetic Technique
All patients were sedated in the preoperative area with intravenous glycopyrrolate (4 µg/kg), midazolam (0.02 mg/kg), and ketamine (1 mg/kg). After transfer to the operating theatre, standard monitoring comprising electrocardiography, non-invasive blood pressure, pulse oximetry, and capnography was instituted. Patients were preoxygenated with 100% oxygen for 3 minutes. Intravenous fentanyl (2 µg/kg) was administered before induction of anesthesia with propofol (2 mg/kg). Following confirmation of adequate mask ventilation, atracurium (0.5 mg/kg) was administered to facilitate neuromuscular blockade. Anesthesia was maintained with sevoflurane.
An appropriately sized LMA Supreme (size 2 or 2.5), selected according to the manufacturer's weight-based recommendations, was inserted by a senior anesthesiologist using the standard index-finger technique with the patient in the sniffing position under an adequate depth of anesthesia. The cuff was inflated to a pressure of 60 cmH₂O using a cuff pressure manometer. Ease of LMA insertion was assessed using a numerical rating scale (NRS) ranging from 0 (no resistance) to 10 (failed insertion). If adequate ventilation could not be achieved, one additional insertion attempt was permitted.
Mechanical ventilation was initiated using volume-controlled ventilation with a tidal volume of 6–8 mL/kg, respiratory rate of 10–20 breaths/min, inspiratory-to-expiratory ratio of 1:2, and end-tidal carbon dioxide maintained between 35 and 40 mmHg.
Ultrasonographic Assessment
Ultrasonographic assessment of LMA position was performed immediately after insertion by an anesthesiologist experienced in airway ultrasonography using a high-frequency linear transducer (4–10 MHz). Two standard scanning planes were evaluated: a transverse view between the hyoid and thyroid cartilages and a parasagittal view of the pharynx and larynx.
Each ultrasonographic view was scored as either 0 (optimal) or 1 (suboptimal) according to predefined anatomical criteria. In the transverse view, a symmetrical cuff shadow with a smooth, well-defined cuff margin was considered optimal. In the parasagittal view, clear visualization of the cuff tip with the cuff and esophagus lying in the same plane was considered optimal. The total ultrasound score ranged from 0 to 2 and was used to classify LMA position as Grade I (score 0), Grade II (score 1), or Grade III (score 2). Grades I and II were considered acceptable placement, whereas Grade III indicated unacceptable placement.
When ultrasonography demonstrated malrotation (>10°) or suboptimal positioning, the LMA was repositioned under real-time ultrasound guidance until an optimal image was obtained. The airway device was then secured in its corrected position.
Leak Test and Fibreoptic Assessment
Following ultrasonographic evaluation, LMA placement was assessed clinically using the airway leak test and anatomically using fibreoptic laryngoscopy (FOL). The leak test was performed to determine the adequacy of the airway seal and leak pressure. Fibreoptic evaluation was carried out by advancing the fibreoptic scope through the LMA tube to visualize the laryngeal inlet, and the view obtained was graded using a standardized fibreoptic scoring system. Ultrasonographic findings, leak test results, and fibreoptic grades were recorded for comparison.
Perioperative airway-related complications, including hypoxia, desaturation, laryngospasm, coughing, failed ventilation, and the need for LMA repositioning, were documented during anesthesia and in the postoperative recovery period.
Statistical Analysis
Statistical analysis was performed using SPSS version 18.0 (SPSS Inc., Chicago, IL, USA). Continuous variables are presented as mean ± standard deviation (SD), while categorical variables are expressed as frequencies and percentages. Data normality was assessed using the Kolmogorov–Smirnov test. Receiver operating characteristic (ROC) curve analysis was used to determine optimal cut-off values, and the corresponding sensitivity and specificity were calculated. The correlation between ultrasonographic grade and leak test findings was assessed using Spearman's rank correlation coefficient. Logistic regression analysis was performed to identify independent predictors of perioperative complications, including age, sex, ASA physical status, and ultrasound-guided repositioning. A two-tailed p value of <0.05 was considered statistically significant.
RESULTS
Thirty-seven pediatric patients were included in the final analysis. The mean age of the study population was 6.47 ± 2.85 years, with a mean body weight of 17.81 ± 5.27 kg and height of 103.46 ± 10.03 cm. The study included predominantly male participants (83.8%). The mean duration of surgery was 51.65 ± 6.93 minutes. Baseline preoperative hemodynamic parameters were stable, with a mean heart rate of 100.78 ± 5.04 beats/min, systolic blood pressure of 102.22 ± 3.94 mmHg, diastolic blood pressure of 58.32 ± 5.18 mmHg, and oxygen saturation of 99.57 ± 0.50%.
Table 1: Demographic characteristics and baseline preoperative parameters of study participants (N=37)
Parameter N=37
Age(Mean± SD) in years 6.47 ± 2.85
Male (%):Female (%) 31(83.8%):6(16.2%)
Weight (kg) (Mean± SD) 17.81 ± 5.27
Height (cm) (Mean± SD) 103.46 ±10.03
Duration of surgery (min) 51.65 ± 6.93
Preoperative Hemodynamics (Mean± SD)
Heart Rate (/min)
Systolic BP (mmHg)
Diastolic BP (mmHg)
SpO2 (%)
100.78 ± 5.04
102.22 ± 3.94
58.32 ± 5.18
99.57 ± 0.5
Values are expressed as mean ± standard deviation (SD) for continuous variables and number (percentage) for categorical variables. SpO₂: peripheral oxygen saturation.
The characteristics of LMA insertion and ventilation parameters are summarized in Table 2. Among the 37 patients, LMA size 2.0 was used most frequently (64.9%), followed by size 2.5 (29.7%) and size 1.5 (5.4%). Successful LMA placement was achieved on the first attempt in 91.9% of patients, while 10.8% required a second attempt. All LMAs were inserted successfully without difficulty, and no additional insertion manoeuvres were required. The mean time required for successful LMA insertion was 10.38 ± 1.46 seconds. The mean peak airway pressure during ventilation was 17.38 ± 0.92 mmH₂O.
Table 2: LMA insertion characteristics and ventilation parameters among study participants (N=37)
Parameter N=37
LMA Number
LMA No. 1.5 2 (5.4%)
LMA No. 2.0 24 (64.9%)
LMA No. 2.5 11 (29.7%)
Attempt for successful insertion
First attempt 34 (91.89%)
Second attempt 3(8.1%)
Ease of insertion yes 37 (100.0%)
Additional manoeuvre required for insertion 0%
time required for successful insertion (seconds)(Mean± SD) 10.38 ± 1.46
Peak Pressure (mm of H2O) (Mean± SD) 17.38 ± 0.92
Values are presented as mean ± standard deviation (SD) for continuous variables and number (percentage) for categorical variables. LMA: laryngeal mask airway.
Among the 37 patients, the leak test demonstrated Grade 0 in all cases, indicating an adequate airway seal. Ultrasonographic assessment showed optimal positioning in 33 patients (89.2%) in both transverse and parasagittal planes, while 4 patients (10.8%) demonstrated suboptimal findings. Based on the combined ultrasound score, 33 patients (89.2%) were classified as acceptable placement (Grade I), whereas 4 patients (10.8%) were categorized as unacceptable placement (Grade III). Fibreoptic assessment showed Grade A findings in 33 patients (89.2%) and Grade B findings in 4 patients (10.8%).
Table 3: Assessment of LMA position using leak test, ultrasonography, and fibreoptic bronchoscopy (N=37)
Sr. No. Assessment Method Grade Frequency, n (%)
1 Leak Test Grading Grade 0 37 (100.0%)
Grade 1 0 (0.0%)
Grade 2 0 (0.0%)
2 USG Grading – Transverse Plane Grade 0 33 (89.2%)
Grade 1 4 (10.8%)
Grade 2 0 (0.0%)
3 USG Grading – Parasagittal Plane Grade 0 33 (89.2%)
Grade 1 4 (10.8%)
Grade 2 0 (0.0%)
4 Final USG Grading Grade 1 33 (89.2%)
Grade 2 0 (0.0%)
Grade 3 4 (10.8%)
5 FOB Grading Grade A 33 (89.2%)
Grade B 4 (10.8%)
Values are expressed as number (percentage). USG: ultrasonography; FOB: fibreoptic bronchoscopy; LMA: laryngeal mask airway. Final USG grading was classified as Grade I and II indicating acceptable LMA placement, while Grade III indicated unacceptable placement.
The agreement between leak test findings and ultrasonographic assessment of LMA position was analyzed using Cohen’s kappa coefficient. The leak test showed substantial agreement with ultrasonographic grading in both transverse and parasagittal planes (κ = 0.66). Similarly, the correlation between leak test findings and final ultrasonographic grading demonstrated substantial agreement (κ = 0.66). The internal consistency assessment showed a Cronbach’s alpha value of 0.76 across all comparisons.
Table 4: Agreement between leak test findings and ultrasonographic assessment of LMA position (N=37)
Comparison Cronbach's Alpha Cohen's Kappa
Leak Test vs. USG Grading (Transverse Plane) 0.76 0.66
Leak Test vs. USG Grading (Parasagittal Plane) 0.76 0.66
Leak Test vs. Final USG Grading 0.76 0.66
USG: ultrasonography; LMA: laryngeal mask airway. Cohen’s kappa was used to assess agreement between assessment methods. A kappa value of 0.61–0.80 indicates substantial agreement.
The assessment of LMA position showed acceptable placement in all patients according to the leak test (100%). In comparison, ultrasonographic assessment identified acceptable positioning in 33 patients (89.2%) and unacceptable positioning in 4 patients (10.8%). Fibreoptic bronchoscopy findings were comparable with ultrasonography, demonstrating acceptable placement in 33 patients (89.2%) and suboptimal placement in 4 patients (10.8%).
Table 5: Comparison of LMA placement assessment methods (N=37)
Assessment Method Acceptable, n Unacceptable, n Total, n
Leak Test 37 0 37
Ultrasonography (USG) 33 4 37
Fibreoptic Bronchoscopy (FOB) 33 4 37
Values are presented as number (percentage). Acceptable placement was defined according to the predefined grading criteria for each assessment method. USG: ultrasonography; FOB: fibreoptic bronchoscopy; LMA: laryngeal mask airway.
DISCUSSION
The present prospective observational study evaluated the role of ultrasonography (USG) in confirming optimal laryngeal mask airway (LMA) placement in pediatric patients and compared its findings with conventional leak test (LT) and fibreoptic laryngoscopic (FOL) assessment. In our study, ultrasonographic evaluation identified suboptimal LMA placement in 10.8% of patients, whereas the leak test indicated adequate placement in all patients. Fibreoptic assessment demonstrated findings comparable with ultrasonography, supporting the potential role of USG as a reliable, non-invasive method for confirmation of LMA position.
Successful LMA placement is commonly assessed clinically by adequate chest excursion, a satisfactory capnogram, effective ventilation, and absence of an audible leak at clinically acceptable airway pressures. However, these clinical indicators confirm functional performance rather than anatomical positioning of the device. Although the leak test remains the most frequently used bedside method for evaluating supraglottic airway device (SAD) placement, its interpretation may be affected by airway conditions such as laryngospasm or bronchospasm and may not accurately reflect the anatomical relationship between the device and laryngeal structures [9]. Fibreoptic assessment is considered the reference technique for evaluating SAD position because it provides direct visualization of the glottic opening and surrounding structures. However, routine use of FOL is limited because it requires specialized equipment, technical expertise, interruption of ventilation during assessment, and may be influenced by airway secretions [10]. In contrast, airway ultrasonography has gained increasing attention because it is rapid, portable, repeatable, non-invasive, and allows continuous assessment without interrupting ventilation. Recent advances have expanded its role from airway evaluation to real-time dynamic airway management [6,7]. In the present study, although all patients demonstrated adequate ventilation and acceptable leak test results, ultrasonography detected suboptimal LMA positioning in four patients (10.8%). This finding highlights that satisfactory ventilation does not always indicate ideal anatomical placement. Previous fibreoptic studies have demonstrated that suboptimal positioning of pediatric LMAs may occur despite adequate ventilation, possibly due to the smaller dimensions of pediatric airways and the potential for partial obstruction of the glottic aperture by the LMA cuff or tip [11].
Optimal positioning of the LMA is essential to ensure effective ventilation and minimize complications such as mucosal trauma, epiglottic displacement, airway obstruction, gastric insufflation, and aspiration risk [12]. In our study, ultrasound-guided assessment allowed identification of malpositioned devices, which could then be corrected to achieve optimal positioning. The ability of USG to provide real-time anatomical information may therefore offer an advantage over conventional clinical tests. Previous studies have demonstrated a relationship between airway pressure measurements and correct LMA positioning in adults [13]. Similarly, ultrasound-based grading of LMA position has shown good correlation with fibreoptic findings in adult patients [14]. Our findings extend these observations to the pediatric population, where anatomical differences may make confirmation of device position even more important. A suboptimally positioned LMA may still provide adequate ventilation initially but carries a risk of displacement during surgical manipulation or changes in airway pressure. Therefore, ensuring optimal placement is particularly important in children. Previous pediatric studies using fibreoptic assessment have reported variable rates of suboptimal LMA positioning, with repositioning required in approximately 12.8–49% of cases [15,16,17]. In our study, the rate of suboptimal LMA placement detected by USG was 10.8%, whereas the leak test identified no cases of suboptimal placement. Similar findings were reported by Arican et al., who demonstrated that ultrasonography detected suboptimal LMA placement despite satisfactory clinical assessment. They reported suboptimal placement in 20.8% of patients following ultrasound evaluation, with some devices requiring correction or repositioning. A significant correlation was observed between ultrasound grading and leak test findings, supporting the usefulness of ultrasound as an adjunctive assessment tool.[18]
In the present study, the agreement between leak test and ultrasound assessment was substantial, with a Cohen’s kappa value of 0.66. Furthermore, ultrasound findings correlated well with fibreoptic assessment, with both techniques identifying 89.2% acceptable and 10.8% unacceptable LMA positions. These findings suggest that ultrasonography can provide anatomical confirmation comparable to fibreoptic assessment while avoiding the invasiveness and technical limitations associated with FOL.
The present study has some limitations. The sample size was relatively small, and the study was conducted at a single center. Additionally, ultrasound assessment requires operator experience, which may influence reproducibility. Larger multicenter studies are required to validate standardized ultrasound criteria for routine assessment of pediatric LMA placement.
In conclusion, ultrasonography is a useful, non-invasive, and reliable technique for confirming LMA position in pediatric patients. While the leak test remains valuable for assessing functional airway adequacy, ultrasound provides additional anatomical information and may improve the detection of suboptimal LMA placement.
REFERENCES
1. Yu SH, Beirne OR. Laryngeal mask airways have a lower risk of airway complications compared with endotracheal intubation: a systematic review. J Oral Maxillofac Surg. 2010;68(10):2359-2376.
2. Song K, Yi J, Liu W, et al. Confirmation of laryngeal mask airway placement by ultrasound examination: a pilot study. J Clin Anesth. 2016;34:638-643.
3. Brimacombe J, Keller C. Laryngeal mask airway size selection in males and females: ease of insertion, oropharyngeal leak pressure, pharyngeal mucosal pressures and anatomical position. Br J Anaesth. 1999;82(5):703-707.
4. Keller C, Brimacombe J, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth. 1999;82(2):286-287.
5. Shimbori H, Ono K, Miwa T, et al. Comparison of the LMA-ProSeal and LMA-Classic in children. Br J Anaesth. 2004;93(4):528-531.
6. Kundra P, Mishra SK, Ramesh A. Ultrasound of the airway. Indian Journal of Anaesthesia 2011; 55 (5): 456-462. doi: 10.4103/0019-5049.89868
7. Kristensen MS. Ultrasonography in the management of the airway. Acta Anaesthesiologica Scandinavica 2011; 55 (10): 1155-1173. doi: 10.1111/j.1399-6576.2011.02518.x
8. Kim J, Kim JY, Kim WO, et al. An ultrasound evaluation of laryngeal mask airway position in pediatric patients: an observational study. Anesth Analg. 2015;120:427---3
9. Theiler L, Kleine-Brueggeney M, Urwyler N, Graf T, Luyet C, Greif R. Randomized clinical trial of the i-gel and Magill tracheal tube or single-use ILMA and ILMA tracheal tube for blind intubation in anaesthetized patients with a predicted difficult airway. British Journal of Anaesthesia. 2011;107(2):243-250.
10. Abraham A. Gold standards and anaesthesia. Indian Journal of Anaesthesia. 2013;57(2):207-209.
11. Von Ungern-Sternberg BS, Wallace CJ, Sticks S, et al. Fibreoptic assessment of paediatric sized laryngeal mask airways. Anaesthesia and Intensive Care. 2010;38:50-54.
12. Daya H, Fawcett WJ, Weir N. Vocal fold palsy after use of the laryngeal mask airway. Journal of Laryngology and Otology. 1996;110:383-384.
13. Joshi S, Sciacca RR, Solanki DR, et al. A prospective evaluation of clinical tests for placement of laryngeal mask airways. Anesthesiology. 1998;89:1141-1146.
14. Gupta D, Srirajakalidindi A, Habli N, et al. Ultrasound confirmation of laryngeal mask airway placement correlates with fiberoptic laryngoscope findings. Middle East Journal of Anaesthesiology. 2011;21:283-287.
15. Ghai B, Ram J, Makkar JK, et al. Fiber-optic assessment of LMA position in children: a randomized crossover comparison of two techniques. Paediatric Anaesthesia. 2011;21:1142-1147.
16. Soh CR, Ng AS. Laryngeal mask airway insertion in paediatric anaesthesia: comparison between the reverse and standard techniques. Anaesthesia and Intensive Care. 2001;29:515-519.
17. Tsujimura Y. Downfolding of the epiglottis induced by the laryngeal mask airway in children: a comparison between two insertion techniques. Paediatric Anaesthesia. 2001;11:651-655.
18. Arican S, Pekcan S, Hacibeyoglu G, Yusifov M, Yuce S, Tuncer Uzun S. The place of ultrasonography in confirming the position of the laryngeal mask airway in pediatric patients: an observational study. Braz J Anesthesiol. 2021;71(5):523-529. doi:10.1016/j.bjane.2020.12.014.
Recommended Articles
Original Article
Parental Awareness Regarding Clubfoot and Developmental Dysplasia of the Hip (DDH): A Knowledge, Attitude and Practice (KAP) Study
A prospective cohort study to evaluate serial sequential organ failure assessment scoring (SOFA score) and outcomes of patients in trauma intensive care unit of tertiary care hospital.